MIL-DTL-21393B
TABLE I. Standard/Service Conditions.
Standard
Service
Parameter
conditions
conditions
Room ambient (30º ±10ºC)
Temperature
Operating: (-40ºC to 71ºC),
Non-operating: (-57ºC to +85ºC)
Altitude
Normal ground
Operating (Sea level to 15,000 feet),
Non-operating (Sea level to 40,000 feet)
Vibration
None
Microphones should withstand random
excitation over the frequency range of 15
to 2,000 Hz, with energy density levels
specified by the appropriate figure and
table of MIL-STD-810, method 514,
Humidity
Room ambient up to 90%
The microphones should withstand the
relative humidity
effects of humidities up to 100 %,
including conditions wherein
condensation takes place in and on the
equipment. The equipment should
withstand the above conditions during
operating and non- operating conditions.
4.2 Test equipment and inspection facilities. Test and measuring equipment and inspection facilities of
sufficient accuracy, quality, and quantity to permit performance of the required inspection shall be
established and maintained by the contractor. The establishment and maintenance of a calibration
system to control the accuracy of the measuring and test equipment [i.e., non-Government standard
(NGS) or Federal or Military standard] shall be in accordance with NCSL Z540-1 or equivalent.
4.3 First article inspection (microphone only). When required (see 6.2d), first article inspection shall
consist of all of the tests in table II.
4.3.1 Sample size. With the exception of the reliability test, 10 (ten) microphones shall be submitted
for first article inspection. For quantity related to reliability test, see table VIII. The units selected shall be
representative of "production configuration" in design, materials, construction and performance.
4.3.2 Inspection routine. The sample shall be subjected to the inspections specified in table II, in the
order shown. All sample units shall be subjected to the inspections of group I. The sample shall then be
divided equally into two groups of five (5) units each. One group shall be subjected to the group II
inspections, and the other group shall be subjected to group III inspections.
4.3.3 Failures. If one or more sample units fail to pass any group inspections, the sample lot shall be
considered to have failed.