MIL-DTL-24223/4B(SH)
GREEN
MCC COM -
MC 70V +
MC 95V +
RED
FIGURE 3. Wiring diagram and terminal designations.
ENVIRONMENTAL REQUIREMENTS:
Temperature: Temperature shall be from -20.2 to 149 °F (-29 to 65 °C).
Gun blast: After gun blast testing the equipment shall show no damage and meet the acoustic performance after
salt spray, vibration, and shock tests requirements of MIL-DTL-24223, except the level shall be within 3 dB of the
values measured before gun blast test. "Damage" is interpreted as evidence of rupture, fracture, tearing, or
mechanical deformation that would impair the operation of the device.
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes
with respect to the previous issue due to the extent of the changes.
Preparing Activity:
Navy SH
(Project 5965-2012-006)
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.dla.mil.