4.4.3 Group C inspection. Group C inspection shall be performed on units that have passed group A and group B
inspection. The inspection shall consist of the inspection specified in table III.
4.4.3.1 Sampling for group C inspection. For subgroup I, two samples each of the handset shall be selected at
random from each 500 units or fraction thereof produced. Each sample shall be tested to all tests of the subgroup.
For subgroup II, five samples shall be selected at random from each 1,000 units or fraction thereof produced. One
sample shall be tested against each test. For subgroup III, two samples shall be selected at random from each 2,000
units or fraction thereof produced. One sample shall be tested against each test. The first samples of each test
subgroup shall be selected from the first production lot.
4.4.3.2 Group C failures. Actions required relative to group C failures shall be as specified in the contract or
purchase order.
4.4.4 Reinspection of conforming group C sample units. Unless otherwise specified, sample units which have
been subjected to and passed group C inspection may be accepted on contract provided all damage is repaired and
the sample units are re-subjected to and pass group A and group B inspection.
TABLE III. Group C inspection.
Inspection
Requirement
Inspection
paragraph
paragraph
Subgroup I
Carbon noise
Leakage (Immersion)
Subgroup II
Temperature
Humidity
Altitude (Elevation)
Vibration
Aging
Subgroup III
Endurance
Blast
4.4.5 Rejection and retest. When one or more items fail to meet the specification, acceptance of all items will be
withheld until the extent and cause of failure are determined. After corrections have been made, all necessary tests
shall be repeated.
4.4.5.1 Sampling plan. Accept on zero, for general inspection as specified in table IV, table V or table VI.