MIL-DTL-9415B
TABLE IX. First Article and conformance inspection.
Inspection or Test
Requirement
Test
First
Individual
Sampling
1/
paragraph
paragraph
article
A. Visual and mechanical inspection
All
All
All
B. Electrical tests
1. Loudspeaker:
All
All
All
All
All
Voice coil polarity
All
--
All
Voice coil polarity impedance
All
--
All
Sensitivity
All
All
All
All
Response frequency characteristic
--
All
All
Acoustic quality
--
All
All
Ruggedness
--
All
--
Directional characteristics
--
All
All
Linearity
Distortion-frequency characteristic
2. AF Amplifier AM-492B/AIC-10:
All
Performance in normal condition:
All
All
All
Gain (normal)
All
All
--
Frequency response (normal)
All
All
--
Distortion (normal)
All
All
Input-output characteristics (normal)
Performance in call condition:
--
All
All
Gain (call)
--
All
All
Frequency response (call)
All
All
All
Distortion (call)
All
All
All
Amplifier output with ON-OFF switch in OFF
All
position
All
All
Noise in output due to ripple on dc line
--
All
All
--
Phasing
All
All
Microphone noise
--
3. Complete Assembly:
--
--
Stray magnetic field
--
All
All
Overall performance
All
All
C. Service-condition tests, complete assembly:
--
Loudspeaker lead wire flexibility
2
--
--
Lead wire clamp efficiency
All
All
Disengagement force of loudspeaker lead
All
All
All
connector
Loudspeaker lead connector life test
--
2 pair
--
Extreme operating temperature
--
2
All
Temperature cycling
2
--
All
Pressure cycling
2
--
--
Humidity
2
--
3 out of
Vibration
2
--
every
Shock
2
--
1000
Fungus
2
--
3 out of
Salt spray
2
--
every
Explosive decompression
2
--
1000
Gun blast
--
2
--
Explosion proof
2
--
--
1 out of
every
1000
--
--
1/ For sampling plan, see 4.4.2.2
18